https://www.micropressuregauges.in
919820166955
Magnetic Piston Operated Differential Pressure Gau

Magnetic Piston Operated Differential Pressure Gauges

INR 0

Enquire

Description

Micro Magnetic Differential Pressure Gauges are designed to measure the difference in pressure between two points (High & Low) in a system where static pressure is very high. Technical Specifications: Nominal size – Ø 40, 63, 80, 100 & 150 mm Accuracy – ±2.5% of FS (Ascending) (±2% of FS Optional) Case & Bezel – SS 304 case with Nitrile Rubber sealing ring at front Ingress Protection – IP 65 as per EN 60 529 or IS/IEC 60 529 IP 68 as per IS/IEC 60 529 - Optional Pressure element – Compression Spring SS 304 Magnetic Piston – Hard Ferrite Static Pressure – 100 bar (Standard) (200, 450 & 700 bar Optional) Housing (Wetted Parts) – Aluminium (Standard) / SS 316 / SS 316L / Aluminium Housing with SS 316 Sleeve) Dial – Aluminium – Pre-coated White with black marking over 90° arc ± 5° Pointer – Aluminium – Black Finish Fix Type Window – Clear Acrylic Sealing Material – Nitrile Rubber (Standard) (EPDM & Viton Rubber Optional) Process Connection – 1/4” BSP (Female) Standard Permissible temperature – Ambient : -250C to 650C Process : Maximum 800C (Standard) (200° C Optional) Type of mounting – Inline Mounting Direct Bottom Mounting Direct Back or Panel Back Mounting Pipe or Yoke Mounting Pressure ΔP range – 0… to 10 bar Optional Available features – -) Magnetic Reed Switch (Single SPDT Standard / Double SPDT Optional) (Between 20 to 100% of FS) -) Switch Rating: 15 VA, 0.5 Amps, 230 V AC / 200 VDC or 100VA, 1.0 Amps, 230 V AC / 200 VDC -) Liquid Filled Case -) Maximum pointer Follower -) Customized Dial -) Customized Mounting Application – Filter Manufacturer / Water treatment plant / Textile Machinery / Air dryer system / Pharmaceutical industries / Air, Gas & Liquid media Operating Principle – High & Low pressures are separated by a sensor assembly consisting of a magnet, piston, Teflon seal and a range spring. The difference in pressure causes the sensor assembly to move in proportion to the change against a range spring. A rotary magnet located in a separate body cavity and isolated from the acting pressures, is rotated by magnetic coupling as per the linear movement of the sensor assembly. A pointer attached to the rotary magnet indicates differential pressure on the dial. Switch: Reed switches are located adjacent to the pressure chamber and are activated by the magnetic field of the sensor assembly.

Subscribe for latest offers and updates.

we hate spam too